Description
Recommended and tested model with WMS is Datalogic Gryphon D432 Plus.
Find the key you would like the suffix every scan using below table:
For WMS purpose F12
Hex 90
Detail Steps
Plug scanner into the USB port.
Wait for the computer to recognise it and report it ready for use (beep sound).
On the following page, there is a sequence of rules that must be followed.
Set the number of characters in the range 00-10. In this case, 01.
Read the corresponding characters as Hex values from the Hex/Numeric table. Valid values are in the range:• 00-7F for RS-232, USB BULK, USB COM, USB Generic HID • 00-9B USB Keyboard.
For F12 Hex is 90.
You may have to Enable Terminator function by scanning below code.
For more Hex code, please refer to attached full manual.
How to check F12 setup successfully
Open blank Word document.
Scan any QR code. It should put the code on word document as well as open Save As window as below.
If Save As does not appear, it means the F12 not setup properly. Repeat the process again.
Related Information